1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
|
/**
* @file llerror.h
* @date December 2006
* @brief error message system
*
* $LicenseInfo:firstyear=2006&license=viewergpl$
*
* Copyright (c) 2006-2008, Linden Research, Inc.
*
* Second Life Viewer Source Code
* The source code in this file ("Source Code") is provided by Linden Lab
* to you under the terms of the GNU General Public License, version 2.0
* ("GPL"), unless you have obtained a separate licensing agreement
* ("Other License"), formally executed by you and Linden Lab. Terms of
* the GPL can be found in doc/GPL-license.txt in this distribution, or
* online at http://secondlifegrid.net/programs/open_source/licensing/gplv2
*
* There are special exceptions to the terms and conditions of the GPL as
* it is applied to this Source Code. View the full text of the exception
* in the file doc/FLOSS-exception.txt in this software distribution, or
* online at http://secondlifegrid.net/programs/open_source/licensing/flossexception
*
* By copying, modifying or distributing this software, you acknowledge
* that you have read and understood your obligations described above,
* and agree to abide by those obligations.
*
* ALL LINDEN LAB SOURCE CODE IS PROVIDED "AS IS." LINDEN LAB MAKES NO
* WARRANTIES, EXPRESS, IMPLIED OR OTHERWISE, REGARDING ITS ACCURACY,
* COMPLETENESS OR PERFORMANCE.
* $/LicenseInfo$
*/
#ifndef LL_LLERROR_H
#define LL_LLERROR_H
#include <sstream>
#include <typeinfo>
#include "llerrorlegacy.h"
/* Error Logging Facility
Information for most users:
Code can log messages with constuctions like this:
LL_INFOS("StringTag") << "request to fizzbip agent " << agent_id
<< " denied due to timeout" << LL_ENDL;
Messages can be logged to one of four increasing levels of concern,
using one of four "streams":
LL_DEBUGS("StringTag") - debug messages that are normally supressed
LL_INFOS("StringTag") - informational messages that are normall shown
LL_WARNS("StringTag") - warning messages that singal a problem
LL_ERRS("StringTag") - error messages that are major, unrecoverable failures
The later (LL_ERRS("StringTag")) automatically crashes the process after the message
is logged.
Note that these "streams" are actually #define magic. Rules for use:
* they cannot be used as normal streams, only to start a message
* messages written to them MUST be terminated with LL_ENDL
* between the opening and closing, the << operator is indeed
writing onto a std::ostream, so all conversions and stream
formating are available
These messages are automatically logged with function name, and (if enabled)
file and line of the message. (Note: Existing messages that already include
the function name don't get name printed twice.)
If you have a class, adding LOG_CLASS line to the declaration will cause
all messages emitted from member functions (normal and static) to be tagged
with the proper class name as well as the function name:
class LLFoo
{
LOG_CLASS(LLFoo);
public:
...
};
void LLFoo::doSomething(int i)
{
if (i > 100)
{
LL_WARNS("FooBarTag") << "called with a big value for i: " << i << LL_ENDL;
}
...
}
will result in messages like:
WARN: LLFoo::doSomething: called with a big value for i: 283
Which messages are logged and which are supressed can be controled at run
time from the live file logcontrol.xml based on function, class and/or
source file. See etc/logcontrol-dev.xml for details.
Lastly, logging is now very efficient in both compiled code and execution
when skipped. There is no need to wrap messages, even debugging ones, in
#ifdef _DEBUG constructs. LL_DEBUGS("StringTag") messages are compiled into all builds,
even release. Which means you can use them to help debug even when deployed
to a real grid.
*/
namespace LLError
{
enum ELevel
{
LEVEL_ALL = 0,
// used to indicate that all messagess should be logged
LEVEL_DEBUG = 0,
LEVEL_INFO = 1,
LEVEL_WARN = 2,
LEVEL_ERROR = 3, // used to be called FATAL
LEVEL_NONE = 4
// not really a level
// used to indicate that no messages should be logged
};
/* Macro support
The classes CallSite and Log are used by the logging macros below.
They are not intended for general use.
*/
class CallSite;
class Log
{
public:
static bool shouldLog(CallSite&);
static std::ostringstream* out();
static void flush(std::ostringstream*, const CallSite&);
};
class CallSite
{
// Represents a specific place in the code where a message is logged
// This is public because it is used by the macros below. It is not
// intended for public use.
public:
CallSite(ELevel, const char* file, int line,
const std::type_info& class_info, const char* function, const char* broadTag, const char* narrowTag, bool printOnce);
bool shouldLog()
{ return mCached ? mShouldLog : Log::shouldLog(*this); }
// this member function needs to be in-line for efficiency
void invalidate();
private:
// these describe the call site and never change
const ELevel mLevel;
const char* const mFile;
const int mLine;
const std::type_info& mClassInfo;
const char* const mFunction;
const char* const mBroadTag;
const char* const mNarrowTag;
const bool mPrintOnce;
// these implement a cache of the call to shouldLog()
bool mCached;
bool mShouldLog;
friend class Log;
};
class End { };
inline std::ostream& operator<<(std::ostream& s, const End&)
{ return s; }
// used to indicate the end of a message
class NoClassInfo { };
// used to indicate no class info known for logging
}
/*
Class type information for logging
*/
#define LOG_CLASS(s) typedef s _LL_CLASS_TO_LOG
// Declares class to tag logged messages with.
// See top of file for example of how to use this
typedef LLError::NoClassInfo _LL_CLASS_TO_LOG;
// Outside a class declartion, or in class without LOG_CLASS(), this
// typedef causes the messages to not be associated with any class.
/*
Error Logging Macros
See top of file for common usage.
*/
#define lllog(level, broadTag, narrowTag, once) \
{ \
static LLError::CallSite _site( \
level, __FILE__, __LINE__, typeid(_LL_CLASS_TO_LOG), __FUNCTION__, broadTag, narrowTag, once);\
if (_site.shouldLog()) \
{ \
std::ostringstream* _out = LLError::Log::out(); \
(*_out)
// DEPRECATED: Don't call directly, use LL_ENDL instead, which actually looks like a macro
#define llendl \
LLError::End(); \
LLError::Log::flush(_out, _site); \
} \
}
// DEPRECATED: Use the new macros that allow tags and *look* like macros.
#define lldebugs lllog(LLError::LEVEL_DEBUG, NULL, NULL, false)
#define llinfos lllog(LLError::LEVEL_INFO, NULL, NULL, false)
#define llwarns lllog(LLError::LEVEL_WARN, NULL, NULL, false)
#define llerrs lllog(LLError::LEVEL_ERROR, NULL, NULL, false)
#define llcont (*_out)
// NEW Macros for debugging, allow the passing of a string tag
// One Tag
#define LL_DEBUGS(broadTag) lllog(LLError::LEVEL_DEBUG, broadTag, NULL, false)
#define LL_INFOS(broadTag) lllog(LLError::LEVEL_INFO, broadTag, NULL, false)
#define LL_WARNS(broadTag) lllog(LLError::LEVEL_WARN, broadTag, NULL, false)
#define LL_ERRS(broadTag) lllog(LLError::LEVEL_ERROR, broadTag, NULL, false)
// Two Tags
#define LL_DEBUGS2(broadTag, narrowTag) lllog(LLError::LEVEL_DEBUG, broadTag, narrowTag, false)
#define LL_INFOS2(broadTag, narrowTag) lllog(LLError::LEVEL_INFO, broadTag, narrowTag, false)
#define LL_WARNS2(broadTag, narrowTag) lllog(LLError::LEVEL_WARN, broadTag, narrowTag, false)
#define LL_ERRS2(broadTag, narrowTag) lllog(LLError::LEVEL_ERROR, broadTag, narrowTag, false)
// Only print the log message once (good for warnings or infos that would otherwise
// spam the log file over and over, such as tighter loops).
#define LL_DEBUGS_ONCE(broadTag) lllog(LLError::LEVEL_DEBUG, broadTag, NULL, true)
#define LL_INFOS_ONCE(broadTag) lllog(LLError::LEVEL_INFO, broadTag, NULL, true)
#define LL_WARNS_ONCE(broadTag) lllog(LLError::LEVEL_WARN, broadTag, NULL, true)
#define LL_DEBUGS2_ONCE(broadTag, narrowTag) lllog(LLError::LEVEL_DEBUG, broadTag, narrowTag, true)
#define LL_INFOS2_ONCE(broadTag, narrowTag) lllog(LLError::LEVEL_INFO, broadTag, narrowTag, true)
#define LL_WARNS2_ONCE(broadTag, narrowTag) lllog(LLError::LEVEL_WARN, broadTag, narrowTag, true)
#define LL_ENDL llendl
#define LL_CONT (*_out)
/*
Use this construct if you need to do computation in the middle of a
message:
LL_INFOS("AgentGesture") << "the agent " << agend_id;
switch (f)
{
case FOP_SHRUGS: LL_CONT << "shrugs"; break;
case FOP_TAPS: LL_CONT << "points at " << who; break;
case FOP_SAYS: LL_CONT << "says " << message; break;
}
LL_CONT << " for " << t << " seconds" << LL_ENDL;
Such computation is done iff the message will be logged.
*/
#endif // LL_LLERROR_H
|