; * The startup section lists all the connectors to start up in this server
; * instance. This may be only one, or it may be the entire server suite.
; * Multiple connectors should be seaprated by commas.
; *
; * These are the IN connectors the server uses, the in connectors
; * read this config file and load the needed OUT and database connectors
; *
; * Add "OpenSim.Server.Handlers.dll:AuthenticationServiceConnector" to
; * enable the experimental authentication service
; *
[Startup]
ServiceConnectors = "OpenSim.Server.Handlers.dll:AssetServiceConnector,OpenSim.Server.Handlers.dll:InventoryServiceInConnector,OpenSim.Server.Handlers.dll:FreeswitchServerConnector"

; * This is common for all services, it's the network setup for the entire
; * server instance
; *
[Network]
port = 8003

; * The following are for the remote console
; * They have no effect for the local or basic console types
; * Leave commented to diable logins to the console
;ConsoleUser = Test
;ConsolePass = secret

; * As an example, the below configuration precisely mimicks the legacy
; * asset server. It is read by the asset IN connector (defined above)
; * and it then loads the OUT connector (a local database module). That,
; * in turn, reads the asset loader and database connection information
; *
[AssetService]
LocalServiceModule = "OpenSim.Services.AssetService.dll:AssetService"
DefaultAssetLoader = "OpenSim.Framework.AssetLoader.Filesystem.dll"
AssetLoaderArgs = "assets/AssetSets.xml"
StorageProvider = "OpenSim.Data.MySQL.dll"
ConnectionString = "Data Source=localhost;Database=grid;User ID=grid;Password=grid;"

; * This configuration loads the inventory server modules. It duplicates
; * the function of the legacy inventory server
; *
[InventoryService]
LocalServiceModule = "OpenSim.Services.InventoryService.dll:InventoryService"
UserServerURI = "http://127.0.0.1:8002"
SessionAuthentication = "false"
StorageProvider = "OpenSim.Data.MySQL.dll"
ConnectionString = "Data Source=localhost;Database=grid;User ID=grid;Password=grid;"

; * This is the configuration for the freeswitch server in grid mode
[FreeswitchService]
LocalServiceModule = "OpenSim.Services.FreeswitchService.dll:FreeswitchService"

; * This is the new style authentication service. Currently, only MySQL
; * is implemented. "Realm" is the table that is used for user lookup.
; * By setting it to "users", you can use the old style users table
; * as an authentication source.
; *
[AuthenticationService]
AuthenticationServiceModule = "OpenSim.Services.AuthenticationService.dll:PasswordAuthenticationService"
StorageProvider = "OpenSim.Data.MySQL.dll"
ConnectionString = "Data Source=localhost;Database=grid;User ID=grid;Password=grid;"
; Realm = "auth"

; * This is the new style user service.
; * "Realm" is the table that is used for user lookup.
; * It defaults to "users", which uses the legacy tables
; *
[UserAccountService]
AuthenticationServiceModule = "OpenSim.Services.UserService.dll:UserAccountService"
StorageProvider = "OpenSim.Data.MySQL.dll"
ConnectionString = "Data Source=localhost;Database=grid;User ID=grid;Password=grid;"
; Realm = "users"