| Commit message (Collapse) | Author | Files | Lines |
|
opensim-libs). Change BSScene to use new interface.
|
|
collider rather than OPCODE."
This reverts commit 4eef6725f4116aa70de729b71d60636a7d0a68f5.
Reverting for now since this fails with "terminate called after throwing an instance of 'std::bad_alloc'" on Wright Plaza instances.
|
|
The osGetGrid**** functions will now get the grid settings from the GridInfoService. Set the GridInfoURI in your ./bin/config-include/GridCommon.ini [GridInfo] section.
|
|
rather than OPCODE.
As discussed on the opensim-dev mailing list, this is to avoid a demonstrated ODE collider segfault when stress-testing a simulator running more than one region using the bundled pCampbot.exe
As before, the ODE revision used is r1755 - only the collider has changed.
Tests so far reveal little performance change.
However, if noticeable issues do arise, please report on mantis and/or the opensim-dev mailing list.
The previous libraries are temporarily in bin/Physics-previous-ode-libs
These can be copied back to bin if one wants to compare behaviour with the previous libraries.
|
|
adjustment commit.
Left in the method doc.
|
|
monocov was a code coverage attempt 3 years ago which no longer works.
other removed targets have been commented out or unused for a very long time
|
|
location of the user's UAS. This corrects an earlier design which had some cases pointing to the profile server. WARNING: CONFIGURATION CHANGES in both the sims (*Common.ini) and the Robust configs (Robust.HG.ini). Please check diff of the example files, but basically all vars that were pointing to profile should point to the UAS instead and should be called HomeURI.
|
|
separator
|
|
Remove DEBUG option from OpenSim.ini.example as it is handled in the console now with "debug teleport"
|
|
Add configuration option - DEBUG to enable debugging methods. This is temporary for helping users testing teleport routing be able to report back the data with the test cases. We can remove when finished with this, or leave it if it proves to be useful.
Users: set DEBUG = true in OpenSim.ini to get more information from teleport routing. The default is false. It presently prints the TeleportFlags value.
|
|
|
|
in line with all the other ones that are there
|
|
C5 is a collections library and can be found at http://www.itu.dk/research/c5/
This is used in the UDP texture (image) sending code.
|
|
[GridService]. Changed all HG-related .inis, including HyperSimianGrid. No changes in user-facing inis.
|
|
<Files>
<Match pattern="*.cs" recurse="true"/>
<Match pattern="../bin/MyConfig.xml" buildAction="Copy" recurse="false" destination="$(OutputPath)" />
</Files>
|
|
boolean setting in the OpenSim.ini config [Startup] section.
Naturally, default is true.
When set to false, "phantom" flags on prims can be set as usual but all prims remain phantom.
This setting is for test purposes.
This switch does not affect the collision of avatars with the terrain.
|
|
|
|
This was both unused and an invalid jpeg2000 texture from way back in 2008
|
|
|
|
code
|
|
This checks that the initial UseCircuitCode packet is handled correctly for a normal client login.
|
|
|
|
Robust.ini.example to 8002
|
|
|
|
WebFetchInventoryDescendents.
Enabling this by setting Cap_FetchInventoryDescendents2 = "localhost" in the [ClientStack.LindenCaps] section of OpenSim.ini downloads inventory via http rather than udp in later viewers.
|
|
|
|
Adding updated Nini and support to use shell environment variables in OpenSimulator configuration.
Nini @ https://github.com/BlueWall/Nini-Dev
|
|
OpenSim.ini.example.
If anybody was changing this and wondering why there was no effect, this is why.
|
|
This is necessary to see map tiles on v2/v3 viewers and appears to work fine
|
|
This will hopefully address mantis 5471, 5694 and 5718.
This code is now in opensim-libs, along with Diva's slightly older patches (which were already applied to the DLLs in the opensim tree).
Thanks Oren!
|
|
scripts are loading.
From field experience, we know that simulators can be unstable if a user logs in before the scripts have finished loading.
This commit turns login_disable = true in [RegionReady] on by default which prevents this from happening.
If you want the old behaviour, please copy these section from OpenSimDefaults.ini into OpenSim.ini and set login_disable = false
|
|
This only provides enough functionality to allow operations for no money (e.g. sell for $0).
|
|
console prompt
This is to allow broader subsitution in the future. Currently, the only substitions are \R (for region name) and \\ (for a single backslash)
e.g. "Region (\R) " is the current and continuing default prompt
This renames custom_prompt in [Startup] to ConsolePrompt
|
|
Signed-off-by: BlueWall <jamesh@bluewallgroup.com>
|
|
fully functional and cannot be disabled because that would break timings.
|
|
This is to improve the migration of scripts that expect a 20m say distance.
If you want to keep a 30m say distance then please set this as the say_distance parameter in the [Chat] section of OpenSim.ini.
|
|
|
|
|
|
OpenSimDefaults.ini + explanation.
This setting controls the maximum number of listeners in a region
|
|
PARCEL_GROUP, PARCEL_OWNER, ESTATE_MANAGER and REGION_OWNER can be combined with the existing agent uuid option to limit ossl functions to agents and owner classes.
Signed-off-by: BlueWall <jamesh@bluewallgroup.com>
|
|
registers an http poll
|
|
These are disabled by default, as before. Please only turn these on in secure grids, since they allow the same facilities as the existing SetPassword call (also disabled by default)
These facilities can be helpful when integrating external systems, in addition to the existing option of adapting an IAuthenticationService or using WebLoginKey
|
|
like all the others.
This is to make it easier to change all these names at once, where all grids services are running from the same location.
Also rearranges some lines in [Modules] so that StandaloneCommon.ini.example and GridCommon.ini.exmaple are consistent.
|
|
OpenSim needs an asset cache. Running without one will cause problems.
Thanks to Ai Austin for the suggestions in http://opensimulator.org/mantis/view.php?id=4850
|
|
AuthenticationService.
This is switched on by setting AllowSetPassword = true in the [AuthenticationService] section of Robust.ini or Robust.HG.ini
Default is false as before.
|
|
[UserAccountService].
As before, default is false to not allow these calls.
|
|
UserAccountService
Default is false, as before.
Enabling AllowCreateUser in [UserAccountService] for ROBUST allows avatars to be created via an http call, with viewer 2 appropriate bits and pieces.
Only Ruths can be created at present.
Please don't rely on the config since at some point CreateUser will be moved to a separate co-ordinating service.
|
|
As discussed in http://lists.berlios.de/pipermail/opensim-dev/2011-October/010599.html and the preceeding thread mails,
the aim of this setting is to avoid overloading the viewer UDP connection where the client is failing to ack packets.
Please mantis any anomalous viewer connection behaviour which wasn't there before.
|
|
to physics
This had stopped working. However, at the moment it still allows the physics flag to be set even though this has no effect. This needs to be fixed.
Default for this flag is true as previously.
|
|
accidentally delete in 2fbc98f (Jul 7 2011)
|